Skip to content
This repository was archived by the owner on Apr 26, 2023. It is now read-only.

Release Notes

Pablo Conesa edited this page Jun 15, 2017 · 30 revisions
Scipion Logo

v1.1 (2017-06-14) Balbino

Release note

We are very pleased to announce the release of a new version of Scipion. It’s been over a year since the previous and first version and we have been working on 3 main goals for this release:

  • Consolidation: We put and will always put our best effort into making Scipion a robust and reliable software. We have improved performance, usability and fixed multiple bugs.

  • EM packages integration: We have updated several EM packages to their latest versions (relion 2.0.4) and added new ones (motioncor2, gctf, gautomatch, …). Single movie alignment protocol (as in Scipion 1.0) has been split into several ones for each program.

  • Streaming capabilities: To speed up first preprocessing steps we have enabled Scipion to work in “streaming mode”, allowing users to compute aligned movies and estimate CTF as soon as a movie or micrograph comes out of the microscope PC.

New features

EM Packages

Xmipp

Xmipp has been also improved and new methods have been added. Please see xmipp release notes for details.

Automated detection of spherical particles from electron micrographs.

GPU-accelerated particle picking program developed by K. Zhang allows template-based and “gaussian-blob” (no references) picking. All advanced parameters (exclusive picking, filtering etc.) are available.

GPU-accelerated program for CTF determination, refinement and evaluation. At this moment movie options, CTF refinement for particles and tilt refinement options are not supported yet.

We have added Imagic MSA classification method. Further information is available from our wiki.

A general method for the localized three-dimensional reconstruction of substructures bound to a larger particle. After determination of the particle orientations via conventional methods, local areas corresponding to the subunits ('subparticles') can be extracted and treated as single particles.

This program from Grigorieff’s lab allows to estimate and correct magnification distortions in electron micrographs. Correction is also available for particle coordinates. Hint: results of this protocol can be used for motion correction with motioncor2!

Completely re-written (after motioncorr/dosefgpu) software from D. Agard lab allows anisotropic beam-induced motion correction at single pixel level across the whole frame using GPUs. Options for dose filtering, correction of magnification distortion and saving movie stacks are available.

We have updated Relion to its latest available version (2.0.4). You can benefit from the substantial reduction of computing time using Relion with your GPUs. But do not worry if you don’t have GPU, you can also use Relion on CPUs. We have also added new relion extract particle protocol and refactored the picking protocol. Moreover, new protocols for particle sorting, 3D mask creation, projection subtraction and CTF export to STAR file were added.

Streaming

Streaming processing allows to overlap data acquisition with the first steps of digital image processing. Protocols adapted for streaming can be executed even if the algorithm that produces the data that is going to be used as input has only produced part of the output dataset.

Import movies

Movies can now be imported in “streaming” mode. Also, individual frames can be used as input and stacked on-the-fly, making the movies available for later protocols immediately.

Movie alignment

All movie alignment protocols are able to use movies in streaming (motioncorr, motioncor2, xmipp-opticalflow, xmipp-crosscorrelation, unblur).

CTF estimation

ctffind3, ctffind4, gCTF are now able to work in streaming mode.

Monitors

We have designed monitors to follow the status of several running protocols within a Scipion project. They can track and plot values for “system status” (cpu, memory, swap), ctf values (defocusU, defocusV). Alerts can be setup to email the microscopist/user when certain values rise above/below a custom threshold.

HTML Report

The summary monitor generates an HTML report that summarizes the status of the system and the data being processed, plotting the defoci and system data.

Scipion box wizard

This wizard creates a folder structure for your project and can be customized to reflect different microscope or camera setups. You can choose what preprocessing steps you would like to do during movie streaming.

Consolidation

We have also done a lot of work to consolidate Scipion, improving the usability and adding small features to make Scipion a better and more robust software:

  • Extract coordinates protocol can now apply shifts to the particle coordinates.

  • Scipion install script now provides a possibility to choose package version for installation.

  • Export bibliographic references into bibtext file.

  • Notebook: write project notes in your favourite text editor.

  • Labels: any protocol can now be labelled with a name and/or color. This helps to orient within a protocol tree * in large projects. (Use Ctrl+T to loop through modes)

  • Age mode: Coloring the boxes by “age”, the younger the bluest. (Use Ctrl+T to loop through modes)

  • Zooming and panning a project’s protocol tree (Use “Shift + mouse wheel”)

  • Linear picking mode, eraser size modification are now available in xmipp particle picker.

  • Project import: besides import/export of workflows, now it is also possible to import whole projects, e.g. from another computer.

  • Collect statistics: we collect and analyze usage statistics information to better understand the usage of the different protocols and prioritize maintenance and support. You can choose to enable or disable the collection of information at any time.

  • New scripts: create movie stacks, mirror directory, scipion box wizard.

  • Sort objects in browse windows: now all objects can be sorted by name, info or creation date. Useful when you have a lot of different object sets.

  • Highlight direct connections of selected protocols.

  • Several performance improvements to decrease project loading time.

  • Improved movie model: added initial dose (pre-exposure) and dose per frame.

v1.0.1 (2016-06-30)

  • Several protocol fixes:

    • Fixed bug when creating the output for Frealign (in some cases some information from input particles was not properly propagated)

    • Fixed some bugs in movie alignment protocols (summovie and unblur) and tests added

    • Some minor bugs fixed in Relion protocols

    • Bugs fixed in Resmap protocol when using two half volumes

  • Fixed several bugs in Spider protocols:

    • converting input particles with alignment

    • wrong regular expression for replacing some variables in script template

    • parsing of the resulting dendrogram

    • some additional validations and removed unused code

  • Bugfixes and inprovements in Xmipp protocols:

    • Protocols screen-classes merged into one: compare-reprojections

    • Complete refactoring of operate-particles and operate-volumes protocols (previously called 2D and 3D calculator). Tests added

  • Picking and Viewer:

    • Warning if particles are picked in a temporary folder and the SetOfParticles was not created

    • Improved implementation of assign-tiltpairs protocol in Xmipp and some refactoring of picking methods

    • Fixed bug that caused GUI to freeze sometimes

    • Some bugs fixed when displaying and exporting particles

    • Sorting arrows displayed after sorting by a column. Hourglass displayed while sorting.

    • Some bug fixed when creating subset from classes

  • Other fixes or improvements:

    • ImageHandler’s methods convert and writeStack now accepts alignment parameters

    • Fixed bug when displaying Movies summary (sqlite files were not closed)

    • Fixed bug when spawning Eman process to write particles

    • Added REMOTE_MESA_LIB environment var for using OpenGL in remote desktops

    • Created a LegacyProtocol class to read deprecated protocols

    • Cleanup in some tests and added new ones for core classes or functions


v1.0.0 (2016-02-20) Augusto

  • Allows to combine several EM software packages (~ 100 protocols):

    • All protocols from Xmipp

    • Most of protocols from Relion

    • MDA protocols from Spider

    • Some protocols from Eman2/Sparx

    • From Grigorieff lab: CTFFIND, FREALIGN, unblur and summovie.

    • A few tools from Bsoft

    • ResMap, gEMpicker, dogpicker, motioncorr

  • Full tracking and reproducibility:

    • Display runs as a list or a tree.

    • Inspect the parameters of a previous run

    • Repeat one or several runs

    • Export/Import a workflow template

  • Data analysis:

    • Visualization and operation with Sets. (Particles, Micrographs, CTFs, etc)

    • Visualization of Volumes

    • Resolution and angular distribution plots


Clone this wiki locally